SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Mounting Type Features Base Product Number Approval Agency Termination Ingress Protection DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Filter Type Connector Type Material Flammability Rating Number of Positions Panel Cutout Dimensions Connector Style Panel Thickness Current Rating - Appliance Inlet Voltage Rating - Appliance Inlet Current Rating - Filter Switch Features Current Rating - Circuit Breaker Accomodates a Fuse Fuse Holder, Drawer
2-6609944-3 TE Connectivity Corcom Filters 2-6609944-3 27.4881
RFQ
ECAD 4710 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Voltage Selector 6609944 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSC0SSHXA EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
3CFS1 TE Connectivity Corcom Filters 3CFS1 25.9300
RFQ
ECAD 37 0.00000000 TE Connectivity Corcom Filters C, Corcom Bulk Active Panel Mount, Snap-In - 3C CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Affected EAR99 8537.10.9170 36 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 39.12mm IEC 320-C14 0.031" ~ 0.098" (0.79mm ~ 2.49mm) 3A 120/250VAC 3A Switch On-Off - No -
3-6609945-5 TE Connectivity Corcom Filters 3-6609945-5 25.0994
RFQ
ECAD 9906 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609945 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSC00SS3A EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
9-6609947-5 TE Connectivity Corcom Filters 9-6609947-5 22.7756
RFQ
ECAD 3054 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609947 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSJ00DS30 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 3A 120VAC 3A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
5-6609987-2 TE Connectivity Corcom Filters 5-6609987-2 3.6270
RFQ
ECAD 2387 0.00000000 TE Connectivity Corcom Filters SRB, Corcom Bulk Active Panel Mount, Flange, Right Angle Shielded 6609987 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.30.8000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 30.48mm x 22.86mm IEC 320-C14 - 15A 120/250VAC 15A - - No -
5VR7M TE Connectivity Corcom Filters 5VR7M 28.7000
RFQ
ECAD 7 0.00000000 TE Connectivity Corcom Filters ED, Corcom Bulk Active Panel Mount, Flange - 5V CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download RoHS non-compliant Not Applicable REACH Affected EAR99 8536.30.8000 8 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 32.89mm x 23.11mm IEC 320-C14 - 5A 120/250VAC 5A - - No -
6EBS1 TE Connectivity Corcom Filters 6EBS1 19.1200
RFQ
ECAD 100 0.00000000 TE Connectivity Corcom Filters EEB, Corcom Bulk Last Time Buy Panel Mount, Snap-In Shielded 6EBS CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Affected EAR99 8536.69.4030 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 0.031" ~ 0.068" (0.79mm ~ 1.73mm) 6A 120/250VAC 6A - - No -
6EBF1 TE Connectivity Corcom Filters 6EBF1 20.6600
RFQ
ECAD 48 0.00000000 TE Connectivity Corcom Filters EBF, Corcom Bulk Active Panel Mount, Flange - CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.4030 24 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 35.56mm x 25.65mm IEC 320-C14 - 6A 120/250VAC 6A - - No -
1-6609006-9 TE Connectivity Corcom Filters 1-6609006-9 12.5100
RFQ
ECAD 148 0.00000000 TE Connectivity Corcom Filters EEJ, Corcom Bulk Active Panel Mount, Flange, Right Angle - 6609006 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Affected EAR99 8536.30.8000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 30.48mm x 22.86mm IEC 320-C14 - 15A 120/250VAC 15A - - No -
5-6609942-4 TE Connectivity Corcom Filters 5-6609942-4 27.7992
RFQ
ECAD 2207 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Conversion Clip, Shielded 6609942 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 6A 120VAC 6A - - Yes (Fuse Not Included) Fuse Holder
7-6609939-5 TE Connectivity Corcom Filters 7-6609939-5 29.2058
RFQ
ECAD 2886 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded, Voltage Selector 6609939 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 3A 120VAC 3A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
1-6609952-5 TE Connectivity Corcom Filters 1-6609952-5 21.4989
RFQ
ECAD 7169 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Voltage Selector 6609952 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6-6609940-7 TE Connectivity Corcom Filters 6-6609940-7 31.1208
RFQ
ECAD 8226 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded 6609940 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
8-6609940-7 TE Connectivity Corcom Filters 8-6609940-7 35.3100
RFQ
ECAD 64 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded 6609940 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8537.10.9170 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
7-6609960-5 TE Connectivity Corcom Filters 7-6609960-5 19.4219
RFQ
ECAD 2926 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Interconnection Block, Voltage Selector 6609960 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSC0SDBXA EAR99 8536.69.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 64.01mm IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
PS0SXS000 TE Connectivity Corcom Filters PS0SXS000 18.7000
RFQ
ECAD 589 0.00000000 TE Connectivity Corcom Filters P, Chameleon, Corcom Bulk Active Panel Mount, Snap-In Conversion Clip, Voltage Selector PS0S CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8537.10.9170 16 Unfiltered - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.083" (0.79mm ~ 2.11mm) 10A 120VAC - Switch On-Off - Yes (Fuse Not Included) Fuse Holder
15ED1 TE Connectivity Corcom Filters 15ED1 19.7500
RFQ
ECAD 44 0.00000000 TE Connectivity Corcom Filters ED, Corcom Bulk Active Panel Mount, Flange Front or Rear Side Mount CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Affected EAR99 8536.69.4030 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 - 15A 120/250VAC 15A - - No -
5-6609940-6 TE Connectivity Corcom Filters 5-6609940-6 31.8567
RFQ
ECAD 5825 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Conversion Clip, Shielded, Voltage Selector 6609940 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder
PS00XSS6B TE Connectivity Corcom Filters PS00XSS6B 29.9700
RFQ
ECAD 8 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Conversion Clip, Shielded, Voltage Selector PS00 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8537.10.9170 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A - - Yes (Fuse Not Included) Fuse Holder
5-6609944-8 TE Connectivity Corcom Filters 5-6609944-8 24.1669
RFQ
ECAD 6873 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Voltage Selector 6609944 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSC0XDH60 EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
6609016-3 TE Connectivity Corcom Filters 6609016-3 14.3622
RFQ
ECAD 3043 0.00000000 TE Connectivity Corcom Filters ED, Corcom Bulk Active Panel Mount, Flange, Right Angle - 6609016 CSA, UL, VDE Wire Leads - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8548.00.0000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 30.48mm x 22.86mm IEC 320-C14 - 1A 120/250VAC 1A - - No -
2-6609940-7 TE Connectivity Corcom Filters 2-6609940-7 30.1717
RFQ
ECAD 1300 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Shielded, Voltage Selector 6609940 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 12 Filtered (EMI, RFI) - Commercial, Medical Receptacle, Male Blades - Module - 3 Rectangular - 28.45mm x 54.10mm IEC 320-C14 - 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
7-6609959-8 TE Connectivity Corcom Filters 7-6609959-8 -
RFQ
ECAD 5034 0.00000000 TE Connectivity Corcom Filters P, Chameleon, Corcom Bulk Discontinued at SIC Panel Mount, Flange Conversion Clip CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable EAR99 8536.30.8000 60 Unfiltered - Commercial Receptacle, Male Blades - Module - 3 Rectangular - 26.92mm x 54.10mm IEC 320-C14 - 10A 120VAC - Switch On-Off - Yes (Fuse Not Included) Fuse Holder
3-6609929-7 TE Connectivity Corcom Filters 3-6609929-7 27.4821
RFQ
ECAD 5841 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange Conversion Clip, Shielded, Voltage Selector 6609929 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.30.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A Switch On-Off - Yes (Fuse Not Included) Fuse Holder
6609963-5 TE Connectivity Corcom Filters 6609963-5 21.3600
RFQ
ECAD 79 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In Interconnection Block, Voltage Selector 6609963 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8536.69.8000 16 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC 10A Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
20EEJ1 TE Connectivity Corcom Filters 20EEJ1 19.8700
RFQ
ECAD 1 0.00000000 TE Connectivity Corcom Filters EEJ, Corcom Bulk Active Panel Mount, Flange Front or Rear Side Mount 20E CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8537.10.9170 24 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C20 - 20A 120/250VAC 20A - - No -
1-6609008-6 TE Connectivity Corcom Filters 1-6609008-6 10.9115
RFQ
ECAD 7747 0.00000000 TE Connectivity Corcom Filters EJH, Corcom Bulk Active Panel Mount, Snap-In - 6609008 CSA, UL, VDE Quick Connect - 0.250" (6.3mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.30.8000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Variable Size IEC 320-C14 - 1A 120/250VAC 1A - - No -
3-6609987-9 TE Connectivity Corcom Filters 3-6609987-9 3.5845
RFQ
ECAD 1057 0.00000000 TE Connectivity Corcom Filters SRB, Corcom Bulk Active Panel Mount, Flange; Through Hole, Right Angle Shielded 6609987 CSA, UL, VDE Solder - download ROHS3 Compliant 1 (Unlimited) Vendor Undefined EAR99 8536.30.8000 40 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - 3 Rectangular - 30.48mm x 22.86mm IEC 320-C14 - 15A 120/250VAC 15A - - No -
6-6609960-6 TE Connectivity Corcom Filters 6-6609960-6 17.1638
RFQ
ECAD 4949 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Snap-In - 6609960 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant Not Applicable REACH Unaffected PSCS0D000 EAR99 8536.69.8000 16 Unfiltered - Commercial Receptacle, Male Blades - Module - 3 - IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 10A 120VAC - Switch On-Off - Yes (Fuse Not Included) Fuse Holder, Twin Fused
PE000DL6C TE Connectivity Corcom Filters PE000DL6C 53.4000
RFQ
ECAD 7 0.00000000 TE Connectivity Corcom Filters P, Corcom Bulk Active Panel Mount, Flange - PE00 CSA, UL, VDE Quick Connect - 0.187" (4.7mm) - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8536.30.8000 8 Filtered (EMI, RFI) - Commercial Receptacle, Male Blades - Module - 3 Variable Size IEC 320-C14 0.031" ~ 0.114" (0.79mm ~ 2.90mm) 6A 120VAC 6A - - Yes (Fuse Not Included) Fuse Holder, Twin Fused
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse