SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Standard Number
TMV 2-2412DHI Traco Power TMV 2-2412DHI 12.9300
RFQ
ECAD 6 0.00000000 Traco Power TMV 2HI (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.5mm x 10.2mm) Through Hole 7-SIP Module, 5 Leads Isolated Module SCP TMV 2 26.4V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1810 EAR99 8504.40.9580 10 2 W 2 84mA, 84mA 21.6V 81% 12V -12V - - 5.2 kV
TSR 3-24150 Traco Power TSR 3-24150 32.4000
RFQ
ECAD 911 0.00000000 Traco Power TSR-3 Box Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.61" L x 0.37" W x 0.24" H (15.5mm x 9.4mm x 6.2mm) Through Hole 5-SIP Module Linear Regulator Replacement Remote On/Off, SCP TSR 3 30V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1320 EAR99 8504.40.9580 10 45 W 1 3A 10V 95% 5 ~ 15V - - -
TMR 2-4813WISM Traco Power TMR 2-4813WISM 22.2940
RFQ
ECAD 4219 0.00000000 Traco Power TMR 2WISM (2W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial) 0.75" L x 0.59" W x 0.34" H (19.0mm x 14.9mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 2 75V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 2 W 1 134mA 18V 83% 15V - - - 1.5 kV
TMR 6-1213 Traco Power TMR 6-1213 23.5100
RFQ
ECAD 12 0.00000000 Traco Power TMR 6 (6W) Tube Active -40°C ~ 65°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 6 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 6 W 1 400mA 9V 85% 15V - - - 1.6 kV
TDN 3-2422WI Traco Power TDN 3-2422WI 24.6700
RFQ
ECAD 10 0.00000000 Traco Power TDN 3WI (3W) Tube Active -40°C ~ 70°C ITE (Commercial) 0.52" L x 0.36" W x 0.40" H (13.2mm x 9.1mm x 10.2mm) Through Hole 7-DIP Module, 6 Leads Isolated Module Remote On/Off, SCP TDN 3 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 125mA, 125mA 9V 82% 12V -12V - - 1.6 kV
TMR 4-2422 Traco Power TMR 4-2422 16.3400
RFQ
ECAD 39 0.00000000 Traco Power TMR 4 (4W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off TMR 4 CB, cURus, UL 36V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TMR4-2422 EAR99 8504.40.9580 10 4 W 2 - 166mA, 166mA 18V 86% 12V -12V - - 1.92 kV
TEN 6-1212N Traco Power TEN 6-1212N 21.0400
RFQ
ECAD 10 0.00000000 Traco Power TEN 6N (6W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 7 Leads Isolated Module OCP, SCP TEN 6 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 6 W 1 500mA 9V 82% 12V - - - 1.5 kV
TRN 3-4812SM Traco Power TRN 3-4812SM 21.8400
RFQ
ECAD 5897 0.00000000 Traco Power TRN 3SM (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.47" L x 0.44" W x 0.31" H (11.9mm x 11.3mm x 8.0mm) Surface Mount 7-SMD Module, 6 Leads Isolated Module SCP TRN 3 75V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 250mA 36V 83% 12V - - - 1.6 kV
TMR 3-2410WIR Traco Power TMR 3-2410WIR 27.2200
RFQ
ECAD 5615 0.00000000 Traco Power TMR 3WIR (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, SCP TMR 3 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1986 EAR99 8504.40.9580 10 2.3 W 1 700mA 9V 76% 3.3V - - - 3 kV
TMA 0515S Traco Power TMA 0515S 5.3100
RFQ
ECAD 862 0.00000000 Traco Power TMA (1W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.40" H (19.5mm x 6.1mm x 10.2mm) Through Hole 6-SIP Module, 4 Leads Isolated Module SCP TMA 0515 5.5V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2719 EAR99 8504.40.9580 10 1 W 1 67mA 4.5V 78% 15V - - - 1 kV
TMV 1212EN Traco Power TMV 1212EN 12.6500
RFQ
ECAD 17 0.00000000 Traco Power TMV-EN (1W) Tube Active -25°C ~ 85°C (With Derating) ITE (Commercial) 0.87" L x 0.30" W x 0.49" H (22.0mm x 7.5mm x 12.5mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TMV 1212 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2508 EAR99 8504.40.9580 10 1 W 1 80mA 10.8V 66% 12V - - - 3 kV
TEN 8-2411WI Traco Power TEN 8-2411WI 37.7400
RFQ
ECAD 445 0.00000000 Traco Power TEN 8WI (8W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 1.26" L x 0.80" W x 0.40" H (32.0mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEN 8 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2708 EAR99 8504.40.9580 10 8 W 1 1.6A 9V 87% 5V - - - 1.5 kV
TEN 8-1222 Traco Power TEN 8-1222 33.2900
RFQ
ECAD 61 0.00000000 Traco Power TEN 8 (8W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.26" L x 0.80" W x 0.40" H (32.0mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP TEN 8 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2219 EAR99 8504.40.9580 10 8 W 2 335mA, 335mA 9V 87% 12V -12V - - 1.5 kV
TRI 10-2413 Traco Power TRI 10-2413 60.3600
RFQ
ECAD 9 0.00000000 Traco Power TRI 10 (10W) Tube Active -40°C ~ 85°C ITE (Commercial) 1.25" L x 0.80" W x 0.47" H (31.8mm x 20.3mm x 12.0mm) Through Hole 24-DIP Module, 5 Leads Isolated Module - TRI 10 CB, cURus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected TRI10-2413 EAR99 8504.40.9580 10 10 W 1 - 666mA 18V 88% 15V - - - 5 kV
TES 1-1222V Traco Power TES 1-1222V 11.5500
RFQ
ECAD 25 0.00000000 Traco Power TES 1V (1W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.64" L x 0.31" W x 0.31" H (16.3mm x 8.0mm x 8.0mm) Surface Mount 12-SMD Module, 10 Leads Isolated Module SCP TES 1 13.2V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-2457 EAR99 8504.40.9580 10 1 W 2 42mA, 42mA 10.8V 80% 12V -12V - - 3 kV
THM 30-4813 Traco Power THM 30-4813 87.3320
RFQ
ECAD 2919 0.00000000 Traco Power THM 30 (30W) Tube Active -40°C ~ 80°C (With Derating) Medical 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 30 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1684 EAR99 8504.40.9580 10 30 W 1 2A 36V 89% 15V - - - 5 kV
TEN 8-4823WI Traco Power TEN 8-4823WI 41.6300
RFQ
ECAD 14 0.00000000 Traco Power TEN 8WI (8W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 1.26" L x 0.80" W x 0.40" H (32.0mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, OVP, SCP, UVLO TEN 8 75V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1597 EAR99 8504.40.9580 10 8 W 2 267mA, 267mA 18V 87% 15V -15V - - 1.5 kV
THN 20-2413WIR Traco Power THN 20-2413WIR 55.0200
RFQ
ECAD 4 0.00000000 Traco Power THN 20WIR (20W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off THN 20 CB, cURus 36V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-THN20-2413WIR EAR99 8504.40.9580 10 20 W 1 - 1.33A 9V 89% 15V - - - 2.25 kV 50155; 62368-1
TMR 9-2415WI Traco Power TMR 9-2415WI 42.9800
RFQ
ECAD 10 0.00000000 Traco Power TMR 9WI (9W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module, 6 Leads Isolated Module Remote On/Off, SCP TMR 9 CB, cURus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 9 W 1 375mA 9V 89% 24V - - - 1.6 kV
TIM 3.5-0912 Traco Power TIM 3.5-0912 36.8000
RFQ
ECAD 8 0.00000000 Traco Power TIM 3.5 (3.5W) Tube Active -40°C ~ 90°C (With Derating) Medical 0.96" L x 0.57" W x 0.40" H (24.3mm x 14.4mm x 10.2mm) Through Hole 16-DIP Module, 7 Leads Isolated Module Remote On/Off, OVP, SCP TIM 3.5 12V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1749 EAR99 8504.40.9580 10 3.5 W 1 292mA 4.5V 81% 12V - - - 5 kV
THL 3-2415WISM Traco Power THL 3-2415WISM 23.6300
RFQ
ECAD 80 0.00000000 Traco Power THL 3WISM (3W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 0.94" L x 0.54" W x 0.32" H (24.0mm x 13.7mm x 8.3mm) Surface Mount 16-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP THL 3 36V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 125mA 9V 80% 24V - - - 1.5 kV
TEL 15-1213 Traco Power TEL 15-1213 44.1420
RFQ
ECAD 1931 0.00000000 Traco Power TEL 15 (15W) Tube Not For New Designs -40°C ~ 80°C ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module, 4 Leads Isolated Module SCP TEL 15 18V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 15 W 1 1A 9V 86% 15V - - - 1.5 kV
TMR 1-4823 Traco Power TMR 1-4823 10.9710
RFQ
ECAD 3068 0.00000000 Traco Power TMR 1 (1W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.67" L x 0.30" W x 0.43" H (17.0mm x 7.6mm x 11.0mm) Through Hole 6-SIP Module, 5 Leads Isolated Module OCP, SCP TMR 1 CB, CSA 75V Module download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 990 mW 2 - 33mA, 33mA 36V 79% 15V -15V - - 1.5 kV
TDR 3-0523 Traco Power TDR 3-0523 32.5080
RFQ
ECAD 6277 0.00000000 Traco Power TDR 3 (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.74" L x 0.50" W x 0.34" H (18.9mm x 12.8mm x 8.7mm) Through Hole 14-DIP Module, 7 Leads Isolated Module Remote On/Off, SCP TDR 3 9V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 4.5V 81% 15V -15V - - 1.6 kV
TMV 2409SHI Traco Power TMV 2409SHI 9.7100
RFQ
ECAD 3665 0.00000000 Traco Power TMV-HI (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.5mm x 10.2mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TMV 2409 26.4V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 1 W 1 111mA 21.6V 75% 9V - - - 5.2 kV
TRA 3-1211 Traco Power TRA 3-1211 12.2800
RFQ
ECAD 10 0.00000000 Traco Power TRA 3 (3W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.6mm x 10.2mm) Through Hole 6-SIP Module, 4 Leads Isolated Module SCP TRA 3 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 600mA 10.8V 84% 5V - - - 1 kV
TDR 3-1223WISM Traco Power TDR 3-1223WISM 36.1030
RFQ
ECAD 7433 0.00000000 Traco Power TDR 3WISM (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.74" L x 0.50" W x 0.34" H (18.9mm x 12.8mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP TDR 3 18V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 3 W 2 100mA, 100mA 4.5V 81% 15V -15V - - 1.6 kV
TRV 1-1211M Traco Power TRV 1-1211M 14.9700
RFQ
ECAD 24 0.00000000 Traco Power TRV 1M (1W) Tube Active -40°C ~ 85°C ITE (Commercial), Medical 0.77" L x 0.39" W x 0.49" H (19.6mm x 9.9mm x 12.5mm) Through Hole 9-SIP Module, 4 Leads Isolated Module - TRV 1 CB, cURus 14.4V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TRV1-1211M EAR99 8504.40.9580 5 1 W 1 - 200mA 9.6V 82% 5V - - - 5 kV
TRA 3-1213 Traco Power TRA 3-1213 11.9780
RFQ
ECAD 1968 0.00000000 Traco Power TRA 3 (3W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.6mm x 10.2mm) Through Hole 6-SIP Module, 4 Leads Isolated Module SCP TRA 3 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 200mA 10.8V 89% 15V - - - 1 kV
TRN 3-0512SM Traco Power TRN 3-0512SM 22.3900
RFQ
ECAD 10 0.00000000 Traco Power TRN 3SM (3W) Tube Active -40°C ~ 85°C ITE (Commercial) 0.47" L x 0.44" W x 0.31" H (11.9mm x 11.3mm x 8.0mm) Surface Mount 7-SMD Module, 6 Leads Isolated Module SCP TRN 3 13.2V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 250mA 4.5V 82% 12V - - - 1.6 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse