Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Current - Output 1 | Current - Output 2 | Current - Output 3 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RACM40-12S | 99.6900 | ![]() |
59 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM40-12 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 92% | 12V | - | - | - | - | No | 4 kV | 3.34 A | |||||
![]() |
RACM65-12S | 115.6800 | ![]() |
5031 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-12 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 92.5% | 12V | - | - | - | - | No | 4 kV | 5.42 A | ||||
![]() |
RACM40-24S-ST | 98.0100 | ![]() |
9358 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM40-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000254 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 92% | 24V | - | - | - | - | No | 4 kV | 1.67 A | |||
![]() |
RACM40-48S/OF | 78.9100 | ![]() |
6072 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM40-48 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000258 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 93% | 48V | - | - | - | - | No | 4 kV | 840 mA | |||
![]() |
RACM65-12S/OF-ST | 103.6800 | ![]() |
9367 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-12 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000265 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 92.5% | 12V | - | - | - | - | No | 4 kV | 5.42 A | |||
![]() |
RACM65-15S/OF | 100.0800 | ![]() |
6144 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-15 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000267 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 15V | - | - | - | - | No | 4 kV | 4.33 A | |||
![]() |
RACM65-24S/OF | 94.5500 | ![]() |
5 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 24V | - | - | - | - | No | 4 kV | 2.71 A | ||||
![]() |
RACM65-48S-ST | 113.6200 | ![]() |
2804 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-48 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000272 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93% | 48V | - | - | - | - | No | 4 kV | 1.36 A | |||
![]() |
RACM65-48S/OF-ST | 98.1600 | ![]() |
2624 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-48 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000274 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93% | 48V | - | - | - | - | No | 4 kV | 1.36 A | |||
![]() |
RACG100-05S | - | ![]() |
1093 | 0.00000000 | Recom Power | POWERLINE RACG100 (100W) | Box | Obsolete | -20°C ~ 60°C (With Derating) | ITE (Commercial) | 5.08" L x 3.86" W x 1.50" H (129.0mm x 98.0mm x 38.0mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 23000000 | EAR99 | 8504.40.9520 | 1 | 100W | 1 | 84% | 5V | - | - | - | - | No | 3 kV | 20 A | ||||
![]() |
RAC48-24S/OF | - | ![]() |
4569 | 0.00000000 | Recom Power | POWERLINE RAC48/OF (48W) | Box | Obsolete | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.18" H (101.6mm x 50.8mm x 30.0mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | CB, CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 48W | 1 | 85% | 24V | - | - | - | - | - | 3 kV | 2 A | |||||
![]() |
RAC04-24SC/W | 17.5800 | ![]() |
7308 | 0.00000000 | Recom Power | POWERLINE RAC04-SC/W (4W) | Box | Obsolete | -25°C ~ 85°C (With Derating) | ITE (Commercial) | 1.49" L x 0.94" W x 0.65" H (37.8mm x 23.9mm x 16.4mm) | Chassis Mount | Enclosed | DC Input Capable, Remote Sense, Universal Input | RAC04-24 | CB, CE, cURus | 80 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 4W | 1 | 79% | 24V | - | - | - | - | No | 3 kV | 167 mA | ||||
![]() |
RACM18-05SER/W | 44.5100 | ![]() |
177 | 0.00000000 | Recom Power | MEDLINE RACM18-ER/W (18W) | Box | Active | -20°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 2.09" L x 2.00" W x 0.98" H (53.0mm x 51.0mm x 25.0mm) | Chassis Mount | Enclosed | IP68, Universal Input | RACM18-05 | CE | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 13W | 1 | 81% | 5V | - | - | - | - | - | 4.6 kV | 2.5 A | ||||
![]() |
RAC03-3.3SER/277 | 29.5200 | ![]() |
4350 | 0.00000000 | Recom Power | POWERLINE RAC03-SER/277 (3W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.98" L x 1.98" W x 0.43" H (50.3mm x 50.3mm x 11.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC03-3.3 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 12 | 3W | 1 | 68% | 3.3V | - | - | - | - | Yes | 3 kV | 900 mA | ||||
![]() |
RAC03-12SE/277/W | 22.5800 | ![]() |
73 | 0.00000000 | Recom Power | POWERLINE RAC03-E/277/W (3W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.50" L x 0.96" W x 0.69" H (38.1mm x 24.3mm x 17.4mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC03-12 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 30 | 3W | 1 | 78% | 12V | - | - | - | - | Yes | 3 kV | 250 mA | ||||
![]() |
RAC40-0512TA-E-ST | - | ![]() |
4218 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 2 | 40W | 3 | 80% | 5V | 12V | -12V | - | - | - | 4 kV | 5 A | 600 mA | 600 mA | |||
![]() |
RACM40-12S-ST | 103.3700 | ![]() |
8692 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM40-12 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000248 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 92% | 12V | - | - | - | - | No | 4 kV | 3.34 A | |||
![]() |
RAC20-48SK/W | 15.6100 | ![]() |
1562 | 0.00000000 | Recom Power | POWERLINE RAC20-K | Tray | Active | -40°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial) | 2.07" L x 1.08" W x 0.91" H (52.5mm x 27.4mm x 23.0mm) | Chassis Mount | Enclosed | Universal Input | RAC20 | CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20001199 | EAR99 | 8504.40.9510 | 20 | - | 1 | - | 48V | - | - | - | - | 3 kV | |||||
![]() |
RAC15-05SA-ST | - | ![]() |
5032 | 0.00000000 | Recom Power | POWERLINE RAC15-A (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.09" H (111.9mm x 63.7mm x 27.6mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 15W | 1 | 70% | 5V | - | - | - | - | - | 3 kV | 3 A | |||||
![]() |
RAC15-09DB-E-ST | - | ![]() |
3967 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 15W | 2 | 80% | 9V | -9V | - | - | - | - | 4 kV | 833 mA | 833 mA | ||||
![]() |
RAC15-15SA-E-ST | - | ![]() |
6797 | 0.00000000 | Recom Power | POWERLINE RAC15-A (15W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.09" H (111.9mm x 63.7mm x 27.6mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 15W | 1 | 73% | 15V | - | - | - | - | - | 3 kV | 1 A | |||||
![]() |
RAC15-15SB-ST | - | ![]() |
8796 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 5 | 15W | 1 | 82% | 15V | - | - | - | - | - | 4 kV | 1 A | |||||
![]() |
RAC15-24SB-E-ST | - | ![]() |
3358 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 5 | 15W | 1 | 83% | 24V | - | - | - | - | - | 4 kV | 625 mA | |||||
![]() |
RAC15-24SB-ST | - | ![]() |
9017 | 0.00000000 | Recom Power | POWERLINE RAC15-B (15W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.14" H (96.0mm x 53.9mm x 29.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 5 | 15W | 1 | 83% | 24V | - | - | - | - | - | 4 kV | 625 mA | |||||
![]() |
RAC20-05SA-ST | - | ![]() |
7172 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 1 | 20W | 1 | 79% | 5V | - | - | - | - | - | 3 kV | 4 A | |||||
![]() |
RAC20-09DA-ST | - | ![]() |
5922 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 3 | 20W | 2 | 83% | 9V | -9V | - | - | - | - | 3 kV | 1.12 A | 1.12 A | ||||
![]() |
RAC20-12SB-ST | 94.5700 | ![]() |
3784 | 0.00000000 | Recom Power | POWERLINE RAC20-B (20W) | Box | Not For New Designs | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC20 | CE | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 83% | 12V | - | - | - | - | - | 3 kV | 1.67 A | ||||
![]() |
RAC20-24SA-ST | - | ![]() |
2353 | 0.00000000 | Recom Power | POWERLINE RAC20-A (20W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.08" H (111.9mm x 63.7mm x 27.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 84% | 24V | - | - | - | - | - | 3 kV | 840 mA | |||||
![]() |
RAC20-3.3SB-ST | - | ![]() |
3487 | 0.00000000 | Recom Power | POWERLINE RAC20-B (20W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 20W | 1 | 74% | 3.3V | - | - | - | - | - | 3 kV | 3.6 A | |||||
![]() |
RAC30-0512TA-ST | - | ![]() |
7255 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 3 | 77% | 5V | 12V | -12V | - | - | - | 3 kV | 3 A | 630 mA | 630 mA |